The KX-III Busway system is the most versatile product in the E-Line Busway series. The KX-III
Busway is designed,
with the latest innovative technologies such as special epoxy coating and mono-block joint to have
ratings
from 400A to 6000A. The customer has the option to use copper or aluminum conductors in any
configuration of
the KX-III Busway.
The KX-III Busway system is used in a variety of vertical and horizontal electrical distributive
applications, and
typically used in the transmission of energy in facilities with high power applications.The KX-III
Busway comes in
2 types, the feeder and plug in. The feeder busway provides power transmission where tap off boxes
are not
required. The plug-in type can have up to 10 windows per 10 foot section for attaching tap off
boxes.
Since 1973 EAE busway system allows users to distribute electrical energy safely experience in
design and
manufacturing of busway systems.
Power Busway System is a modular energy
transmission and distribution system created by
insulating current carrier Aluminium or Copper
busway conductors placed in a closed body. The
busway system is used to transmit energy to a
point along the route within the facility,
starting from a point such as a transformer,
generator or panel, or to distribute energy to
the loads in the facility by receiving energy
from the current receiving points on it with tap
off boxes.
It is used to feed the floor panels of the
busway system. There are busways in special
lengths and special support systems for the
vertical shaft according to the expansion and
floor height differences of the system.
Conductor
Configuration
Aluminium or Copper Conductor:
4 ½ Conductor
(L1/L2/L3/N/½ PE/ PE Housing)
5 Conductor
(L1/L2/L3/N/PE/ PE Housing)
6 Conductor
(L1/L2/L3/N1/N2/CPE/ PE Housing) – Clean Earth
Advantages of E-Line
KX-III Busway
High short circuit resistance due to compact
construction
Less voltage drop in comparison to cable systems
Special alloy metal enclosure provides higher
mechanical strength and causes less electromagnetic
interference.
Better cooling capability
High resistance to fire
Seismic resistance
Protection Degree (IP55 standard and IP67 optional)
Requires less space in comparison to cable systems
Conductor Material
and Rated Currents
KX-III Series Busway
Aluminium Conductor:
400/500/600/
800/1000/1300/1600/2000/2500/3000/4000 and 5000A
Copper Conductor:
600/800/1000/1250/1600/2000/2500/3200/4000/5000 and 6000A
Different Types to
Suit Varied Applications
Plug-in type (Standard 2 plug-in outlets on both
sides of the 3m enclosure)
Bolt-on type (outlets only at joint)
Plug-in window number can be increased optionally
For aluminium conductors 1000A and above, for copper
conductors 1250A and above bus bar range have
plug-in Windows at both sides